Specim FENIX hyperspectral camera

Hyperspectral Data from VNIR to SWIR in a Single Continuous Image

The Specim FENIX is optimized for the most demanding geological, law enforcement and environmental applications, offering extreme ruggedness and 75% reduction in size and weight compared to previous multi-sensor systems. Due to it's innovative and unique "single optics dual spectrograph" design, the FENIX delivers high-quality, reliable hyperspectral data spanning VNIR to SWIR in a single continuous image.

 

Key Features:

  • Complete spectral range from 380 to 2500 nm
  • Up to 620 spectral bands
  • Readily co-registered data with single fore optic
  • All spectral bands spatially co-registered, independent of target distance
  • Maximized sensitivity and SNR
Specim FENIX hyperspectral camera

Specim FENIX 384

The Specim FENIX 384 features 384 spatial pixels across the VNIR-SWIR range. It operates with default binning of 2 spectral x 2 spatial pixels, providing a spectral sampling of 1.75 nm which is unnecessarily narrow for most applications. This allows for higher spectral binning capabilities while still delivering the required spectral resolution, simultaneously increasing the signal to noise ratio. 

Specim FENIX 1K in an airborne mount with the PCU and DPU stacked beside

Specim FENIX 1K

The Specim FENIX 1K captures the same top-quality full VNIR-SWIR hyperspectral data across 1024 spatial pixels, taking productivity of hyperspectral imaging to an entirely new level. This is an ideal solution for applications requiring fine spatial resolution across a continuous VNIR/SWIR spectral range, and remote sensing where users can reduce the number of flight lines required or opt to collect data with higher accuracy when flying at the same height.

Specim FENIX Key Benefits:

  • Completely Integrated Full VNIR-SWIR Data
  • Maximum Sensitivity and SNR
  • Single Optimized Objective Lens
  • All Spectral Bands Spatially Co-Registered
Specim FENIX hyperspectral camera in airborne mount with PCU

Ideal Solution For:

  • Environmental Monitoring on Fixed-Wing Aircraft
  • Real-Time Airborne Detection
  • Law Enforcement & Defence Applications
  • Mineral Exploration and Mineral Mapping

Technical Specifications

Specification

VNIR

SWIR

Spectrograph High efficiency transmissive imaging spectrograph
Spectral Range 380 - 970 nm 970 - 2500 nm
Spectral Resolution (mean) FENIX: 3.5 nm, FENIX 1K: 2.6 nm (bin 2x) FENIX: 10 nm, FENIX 1K: 8nm (bin 1x)
F/# F/2.4 F/2.4
Smile/Keystone FENIX: <0.2 pixels, FENIX 1K: ± 0.35 pixels FENIX: <0.2 pixels, FENIX 1K: ± 0.35 pixels
Polarization sensitivity Throughput practically independent of polarization
Signal-to-noise ratio (peak) 600-1000:1 FENIX: 1050:1, FENIX 1K: 1250:1
Spatial Resolution FENIX: 384 pixels, FENIX 1K: 1024 pixels
Frame Rate Up to 100 Hz Up to 100 Hz
Integration Time Adjustable within frame period
FOV FENIX: 32.3°, FENIX 1K: 40° FENIX: 32.3°, FENIX 1K: 40°
IFOV FENIX: 0.084°, FENIX 1K: 0.039° FENIX: 0.084°, FENIX 1K: 0.039°
Swath Width FENIX: 0.58 x altitude, FENIX 1K: 0.73 x altitude
Altitude for 1m Pixel Size FENIX: 660 m, FENIX 1K: 1400 m
Electro Mechanical Shutter Yes Yes
Detector CMOS Stirling Cooled MCT
Spectral Binning Options 2 4 8 -
Number of Spectral Bands 348 174 87 FENIX: 274, FENIX 1K: 256
Spectral Sampling/Band 1.7 nm 3.4 nm 6.8 nm FENIX: 5.7 nm, FENIX 1K: 6.3 nm
Data Interface CameraLink 12-bit CameraLink 16-bit
Typical Power Consumption 150 W 150 W